This video will present the application of the Total Wall Adhesively Fastened MD-EIFS system with Liquid Applied Membrane.
-
- Tyvek, NWCB, NCMA’s MSV manual and most One Coat Stucco manufacturer’s call for the weep casing or weep screed to lap the top of the foundation by 1-inch minimum.
- The specified lap that several MD-EIFS manufacturers call for the starter tracks to lap the top of the foundation wall vary from ½-inch to 1-inch minimum. These systems are proprietary; thus, the manufacturer can specify their desired lap of the top of the foundation wall.
- The EDI Standard is for the weep screed, weep casing or starter track to lap the top of the foundation by 1-inch.
- Question: What type of system do you have if you omit the drainage plan and method?
Answer: A Barrier Polymer Based – Barrier EIF System or PB-EIFS.